Post-fire ship hull structure and material assessment

Post-fire ship hull structure and material assessment
Post-fire ship hull structure and material assessment

Fire incidents on ships rank among the most frequent accidents, and in recent years, fire incidents have specially increased among container and ro-ro cargo/ passenger ships. DNV has supported many cases of post-fire structural and material assessments, and this news aims to share our insights from this work.

Need to know

Fire exposure can degrade steel strength and toughness, increasing the risk of brittle behaviour or loss of strength.

An accurate post-fire assessment requires hardness testing (ASTM A370) and, when needed, destructive testing, to determine whether steel grade downgrading or structural repairs are necessary.

What we have observed

DNV has supported ship managers, salvage companies, flag states, shipyards and port authorities by providing expertise and in-depth knowledge on the post-fire structural and material assessment of ships. The incidents have ranged from isolated small-scale fires in cargo holds to major fires damaging the complete ship.

The fire incidents have identified the need for prompt decision-making in situations where time pressure is high and the crew, cargo and environment are at stake. The situations have involved discussions on whether the ship can continue trading, on the extent of steel renewal and repair methods, on a critical reserve strength assessment while the vessel has been on route, and on fire developing rapidly, fuelled by the cargo.

Damage risks from prolonged exposure

Prolonged exposure to high temperatures may result  in soft annealing, leading to a reduction in mechanical properties, in particular tensile strength where the steel becomes softer.

Another effect is the material hardening, a risk that may occur under uncontrolled quenching during firefighting with seawater or CO2. This could primarily affect the material’s ductility by reducing its fracture toughness and therefore increasing the risk of brittle behaviour.

In addition to adverse effects in material mechanical properties, prolonged exposure to thermal loads could result in steel distortions/deformations. The longer the period of heat exposure and heat intensity, the higher the risk that the material properties affecting strength and toughness have been affected. Typically, fire exposure over four to five hours would increase the risk of material and strength deterioration. When post-fire examination reveals permanent waving deformations, this is an indication of long exposure to heat, and material degradation is very probable. If temperatures have not risen over 250–300oC, there is low risk that material would be affected. The extent and magnitude of these deformations would dictate largely the need for repairs.

Steel hardening due to cooling under firefighting

Steel exposed to high temperatures and cooled down rapidly and uncontrollably, due to firefighting water or CO2 release, increases the risk of hardening and of brittle behaviour, especially if occurred in repeated cycles. This is of particular importance in higher grade steels, which may exhibit lower than original post-fire toughness properties.

A conservative approach in emergency situations would be to degrade the material strength by one grade, for example from AH36 (high strength) to NS (normal strength).

Hardness testing

For post-fire strength and repair plan evaluations, as a minimum, hardness testing of the affected steel according to ASTM A370 is required. Both heat- and non-heat- affected materials should be measured to establish a

level of confidence in the measurements. When deemed necessary, destructive testing of samples shall be done under the guidance of DNV (tensile and bend tests as a minimum and location sampling).

Structural repairs

Structural repairs may be dictated by the permanent deformations of the steel plates/stiffeners due to long exposure to thermal load, irrespective of the residual material properties.

Coating condition

A general rule is that if the original coating has no visible signs of damage on the steel surface (e.g. burns, blisters), there is a high probability that the steel has not been adversely affected by the heat input from the fire.

On-going and post-fire support from DNV

In emergency situations, DNV (via DNV ERS™) provides a quick assessment of the residual strength and stability, allowing ship managers and other stakeholders to take crucial decisions on whether to evacuate or initiate firefighting operations to salvage the ship.

As part of the post-fire support, DNV has developed a guideline (to be requested via DNV DATE) that can be used to quickly assess the reserve strength and extent of repairs needed if the steel strength has been affected adversely.

This information is important for ship managers to help them prepare for repairs and make crucial decisions on when and where to schedule these repairs.

The use of drones for post-fire damage surveys by DNV certified service suppliers enables fast access to the affected structure, eliminating the need to secure space for human entry. This significantly reduces time for damage evaluation and speeds up the development of repair plans, eventually leading to efficient planning and reduced off-hire time.

Instagram Posts from the IIMS @iimsmarine

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

Show details Hide details
Performance & Marketing Cookies

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages. This also helps us optimise our marketing campaigns. User data sent to Google Analytics may be used for ad personalization and measurement of our ad campaigns. Keeping this cookie enabled helps us to improve our website.

Show details Hide details