Improper use of heat cables is a fire hazard

USCG LogoThe US Coast Guard (USCG) has recently investigated a fire on board an inspected towing vessel which resulted in the vessel suffering a loss of propulsion. The source of the fire was determined to be heat cables (also referred to as heat tracing cable or heat tape), which were improperly installed to prevent condensate from forming and freezing within hoses used to transmit compressed air for the vessel’s air-operated engine throttle control system.

The heat cables were designed to be installed on fixed piping systems. They were not designed to be used on hoses or in applications which subjected the heat cables to movement. This installation had the heat cables wrapped around hoses connected to a retractable pilot house, which would move whenever the pilot house was raised or lowered. This movement subjected the cables to stresses from flexing and bending for which they were not designed.

The manufacturer’s instructions, National Fire Protections Association (NFPA) 70 the National Electric Code (NEC), and standards from the Institute of Electrical and Electronics Engineers (IEEE) require heat cables to be installed with Ground-Fault Protection and specifically warn that this is required to prevent a fire or electric shock if the heat cable is damaged. Neither the 120-volt receptacle or the circuit breaker which provided power to the heat cables, met this critical safety requirement. Lastly, the insulation utilized to wrap the hoses and the heat cables was not fire-resistant as required by the heat cable manufacturer.

While there are no regulations under Title 46 Code of Federal Regulations (C.F.R.) which specifically address the installation of heat cables, there are regulations which require electrical systems and equipment to be designed, installed, and maintained to provide for the safety of the vessel, and protect persons on board from electrical hazards (including fire and electric shock).

USCG strongly recommends that vessel owners, inspectors, and third-party surveyors:
– Inspect the installation of all heat cables installed on board vessels to ensure they are designed, installed, and maintained in accordance with all manufacturer installation instructions and warnings. This includes strict adherence to bend radius limitations and the use of Ground-Fault protected electrical circuits.
– Heat tracing cables should be listed to meet UL 515 and in consultation with the cable manufacturer, be verified safe for both use in the marine environment and in the intended application on board the vessel3. This is critical to ensuring safe vessel operations and to protect personnel from electrical hazards, to include fire and electric shock.
– For heat cable installations involving vital systems (i.e., propulsion controls, steering systems), a review of potential vulnerabilities of the effected vital system should be conducted. Implement steps to minimize the risk of an unexpected failure of the vital system resulting from a heat cable failure or the Ground-Fault circuit protection tripping off-line
– Implement an inspection and maintenance program as required by the heat cable manufacturer’s instructions. This typically requires insulation resistance readings taken post-installation, and at specified intervals to ensure the insulation is not breaking down. Heat cables with insulation resistances found below the manufacturer’s specified values should be removed and replaced as soon as possible.

Instagram Posts from the IIMS @iimsmarine

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

Show details
Performance & Marketing Cookies

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages. This also helps us optimise our marketing campaigns. User data sent to Google Analytics may be used for ad personalization and measurement of our ad campaigns. Keeping this cookie enabled helps us to improve our website.

Show details