IACS finds common failure modes in emergency generator systems

IACS finds common failure modes in emergency generator systems
IACS finds common failure modes in emergency generator systems

After the loss of power leading up to the MV Dali Francis Scott Key Bridge strike, marine casualty investigators noted an extended delay in the automatic start-up of the ship’s emergency generator. While the small generator was not sufficient in itself to run most major systems, it could provide low-speed hydraulic power to turn the rudder slowly – and could have provided that vital capability much sooner if it had started within standard time parameters, illustrating the importance of automated emergency power start-up.

After the casualty, the National Transportation Safety Board asked the International Association of Class Societies to review emergency generator start-up with members. Separately, the Tokyo MoU also raised concerns about the reliability of standard generator start-up testing procedures involving “simulated blackouts.” In response to the PSC inspection MoU’s request, IACS completed a fleet-wide review via a concentrated inspection campaign, the organization announced Tuesday, and it uncovered a small but meaningful number of deficiencies.

Out of about 37,000 ships inspected across the global fleet, no issues were found with emergency power supply systems in about 98 percent of all cases. The remaining two percent – about 850 ships – showed a pattern of issues that IACS plans to incorporate into its compliance guidance.

Critical and recurring points of failure included:

  • Closing quick-closing valves (22 percent of deficiencies)
  • PCB control circuits (16 percent)
  • Emergency diesel generator starting arrangements (14 percent)

“These failures indicate industry-wide issues with equipment maintenance, installation quality, or component durability,” IACS warned – raising the risk of noncompliance.

Inspectors also found deficiencies in administrative controls and human factors – like a lack of blackout testing procedures in the company SMS, or crew unfamiliarity with the emergency diesel generator and its controls (12 percent of deficiencies).

IACS plans to review and address the findings. It advises that ISM audits should include a realistic test of emergency diesel generator functionality and the operation of the emergency power system as a whole. For frequently-failing components, IACS plans to review its test-and-inspect cycle times in order to catch broken parts sooner.

Instagram Posts from the IIMS @iimsmarine

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

Show details Hide details
Performance & Marketing Cookies

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages. This also helps us optimise our marketing campaigns. User data sent to Google Analytics may be used for ad personalization and measurement of our ad campaigns. Keeping this cookie enabled helps us to improve our website.

Show details Hide details